Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.167
Filter
2.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38451154

ABSTRACT

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Echocardiography, Transesophageal , Treatment Outcome , Cardiac Catheterization/adverse effects , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy
3.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38488065

ABSTRACT

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Subject(s)
Cardiac Catheterization , Heart Septal Defects, Atrial , Humans , Male , Adult , Middle Aged , Female , Retrospective Studies , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Echocardiography, Transesophageal , Fluoroscopy , Treatment Outcome
5.
Cardiol Young ; 34(4): 919-921, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38410075

ABSTRACT

We report an uncommon case report of total anomalous pulmonary venous returns into the right atrium at the base of the superior caval vein's ostium without a sinus venosus defect, in situs solitus, without vertical vein or a posterior pulmonary venous confluence.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Scimitar Syndrome , Humans , Scimitar Syndrome/diagnostic imaging , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/abnormalities , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/diagnostic imaging , Heart Atria/diagnostic imaging , Heart Atria/abnormalities
7.
Pediatr Cardiol ; 45(4): 710-721, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38366300

ABSTRACT

Atrial septal defects (ASDs) are common in neonates. Although past studies suggest ASDs  ≥ 3 mm in term neonates (TNs) are less likely to close, there is paucity of data regarding the natural history in preterm neonates (PNs), information that would inform surveillance. We sought to compare spontaneous closure rates and need for intervention for ASDs in TNs/near term (≥ 36 weeks) versus PNs (< 36 weeks). We included all TNs and PNs who underwent echocardiography at ≤ 1 month between 2010 and 2018 in our institution with an ASD ≥ 3 mm, without major congenital heart disease, and with repeat echocardiogram(s). Spontaneous resolution was defined as size diminution to < 3 mm or closure. We included 156 TNs (mean gestational age at birth 38.6 ± 1.4 weeks) and 156 PNs (29.6 ± 3.7 weeks) with a mean age at follow-up of 16 ± 19 and 15 ± 21 months, respectively (p = 0.76). Based on maximum color Doppler diameter, in TNs, ASD resolution occurred in 95% of small (3-5 mm), 87% of moderate (5.1-8 mm), and 60% of large (> 8 mm) defects; whereas, in PNs, resolution occurred in 79% of small, 76% of moderate, and 33% of large ASDs. There was a significant association between size and ASD resolution in TNs (p = 0.003), but not PNs (p = 0.17). Overall, ASD resolution rate was higher in TNs (89%) versus PNs (78%) (p = 0.009), and fewer TNs (1%) compared to PNs (7%) required ASD intervention (p = 0.02). Most ASDs identified in TNs and PNs spontaneously resolve. PNs, however, demonstrate lower ASD resolution and higher intervention rates within all size groups. These data should inform follow-up of affected neonates.


Subject(s)
Heart Septal Defects, Atrial , Infant, Newborn , Humans , Heart Septal Defects, Atrial/diagnostic imaging , Echocardiography , Ultrasonography, Doppler, Color , Treatment Outcome , Cardiac Catheterization
10.
Int Heart J ; 65(1): 155-158, 2024.
Article in English | MEDLINE | ID: mdl-38296570

ABSTRACT

Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.


Subject(s)
Coronary Sinus , Heart Defects, Congenital , Heart Septal Defects, Atrial , Aged , Humans , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Coronary Sinus/abnormalities , Echocardiography , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Syndrome , Tomography, X-Ray Computed
11.
J Cardiovasc Electrophysiol ; 35(2): 366-369, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38044489

ABSTRACT

INTRODUCTION: In patients with prior atrial septal defect (ASD) closure and atrial tachyarrhythmias, transseptal puncture can be challenging. METHODS AND RESULTS: This case report discusses a 65-year-old man who had previously undergone pulmonary vein isolation (PVI) and cavo-tricuspid isthmus ablation for atrial fibrillation before ASD closure, respectively. He developed atrial tachycardia (AT) and underwent catheter ablation. AT was diagnosed as peri-mitral flutter and the mitral isthmus (MI) linear ablation via a trans-aortic approach successfully terminated it. CONCLUSION: This case demonstrates the feasibility and safety of transaortic MI linear ablation in patients with ASD closure devices or anatomical challenges when transseptal puncture is difficult.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Septal Defects, Atrial , Tachycardia, Supraventricular , Male , Humans , Aged , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/surgery , Heart Atria , Tachycardia/surgery , Catheter Ablation/adverse effects
14.
Cardiovasc Revasc Med ; 58: 90-97, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37596193

ABSTRACT

INTRODUCTION: Multiple device closure (MDC) strategy has been used in treating of complex Atrial septal defects (ASDs) in adults. The safety profile of MDC compared to conventional single device closure (SDC) is unknown in this population. This report represents the first review examining the outcomes of single versus multiple device ASD closure in adults with ostium secundum defects. METHODS: Literature databases and manual search from their inception until June 30th, 2017 followed the Preferred Reporting Items of Systemic Review and Meta-Analysis (PRISMA) guideline. Main outcomes are 1) overall complication incidence, 2) arrhythmia incidence, 3) residual shunt rate. Each outcome profile was pooled by MDC and SDC, respectively and chi-square analysis was applied to examine statistical significance between MDC and SDC strategies (two-sided and p < .050). RESULTS: A total of 1806 + studies were initially screened, and 20 studies were finally selected (MDC group, 147 patients; SDC group, 1706 patients). There was no difference in overall complication incidence (χ2 = 1.269; p = .259) and arrhythmia incidence (χ2 = 0.325; p = .568) between MDC and SDC. There was no difference in residual shunt rate between the SDC (4.10 %; 70/1706) and MDC groups (6.80 %; 10/147; χ2 = 2.387; p = .122). CONCLUSIONS: The outcomes of percutaneous multiple ASD closure (MDC) seem to be safe and effective as compared to conventional single ASD (SDC) closure in terms of device - related complications and technical success of the procedure. Prospective registry data and randomized trials are needed to determine the long-term outcomes of percutaneous ASD closure using MDC.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Adult , Humans , Treatment Outcome , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Prosthesis Design , Arrhythmias, Cardiac/etiology , Cardiac Catheterization/adverse effects
15.
Echocardiography ; 41(1): e15724, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38064288

ABSTRACT

BACKGROUND AND AIM: Our aim was to evaluate the fluoroscopy time (FT), procedure time (PT) safety and efficacy when using intracardiac echocardiography (ICE) in comparison to transesophageal echocardiography (TEE) guidance for transcatheter closure of Ostium Secundum Atrial Septal Defect (OS-ASD). METHOD: Ninety patients (n = 90) diagnosed with OS-ASD underwent transcatheter closure between March 2006 and October 2021. Fifty-seven patients were treated under ICE guidance, while 33 patients were treated under TEE guidance. RESULTS: Mean age was 43 ± 15 years and 42 ± 10 years in the ICE and TEE groups, respectively. The majority of patients had a centrally placed defect. Median FT was 8.40 min versus 11.70 min (p < .001) in the ICE group compared to the TEE group, respectively. Median PT was 43 min versus 94 min (p < .001) in the ICE group compared to the TEE group, respectively. Both ICE and TEE provided high quality images. All interventions were completed successfully, except for one patient in the ICE group who experienced a device migration, the development of atrial tachycardia in one patient and atrial fibrillation in two patients in the ICE group which spontaneously cardioverted. There were no other complications. CONCLUSION: This study on a consistent cohort of patients with OS-ASD undergoing percutaneous closure suggests that use of ICE is safe and efficacious. Compared to TEE, ICE demonstrated significantly shorter FT and PT, decreasing the entire duration of the procedure and x-ray exposure. No relevant differences were observed in terms of success rate and complications.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Humans , Adult , Middle Aged , Echocardiography, Transesophageal/methods , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Fluoroscopy , Treatment Outcome
17.
Eur J Intern Med ; 120: 25-28, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38072687

ABSTRACT

Atrial septal defects (ASD) and Patent foramen ovale (PFO) represent the most common congenital heart diseases (CHD) adulthood. These two clinical entities, having different embryological origin, as well as clinical manifestations, clinical course and treatment must be carefully distinguished. Right heart failure and pulmonary hypertension are considered the major determinants of morbidity and mortality in ASD. Conversely, new pathophysiology concepts have been raised in the management of PFO as left atrium cardiopathy. New diagnostic tools, including cardiac magnetic resonance and intracardiac echocardiography have joint transthoracic and transesophageal echocardiography in the diagnostic definition of both ASD and PFO as well as in guiding their percutaneous closure. Moreover, several innovations have been developed in the field of percutaneous ASD and PFO closure devices including new evidence supporting the safety and efficacy of device-based closure. Aim of the present review is to present review we provided and update overview on ASD and PFO, focusing on the novel concepts regarding their pathophysiological and therapeutic aspects.


Subject(s)
Foramen Ovale, Patent , Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Adult , Treatment Outcome , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Echocardiography, Transesophageal , Heart Atria/diagnostic imaging , Cardiac Catheterization
18.
Radiol Med ; 129(1): 48-55, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38082195

ABSTRACT

OBJECT: The purpose of this study was to explore a machine learning-based residual networks (ResNets) model to detect atrial septal defect (ASD) on chest radiographs. METHODS: This retrospective study included chest radiographs consecutively collected at our hospital from June 2017 to May 2022. Qualified chest radiographs were obtained from patients who had finished echocardiography. These chest radiographs were labeled as positive or negative for ASD based on the echocardiographic reports and were divided into training, validation, and test dataset. Six ResNets models were employed to examine and compare by using the training dataset and was tuned using the validation dataset. The area under the curve, recall, precision and F1-score were taken as the evaluation metrics for classification result in the test dataset. Visualizing regions of interest for the ResNets models using heat maps. RESULTS: This study included a total of 2105 chest radiographs of children with ASD (mean age 4.14 ± 2.73 years, 54% male), patients were randomly assigned to training, validation, and test dataset with an 8:1:1 ratio. Healthy children's images were supplemented to three datasets in a 1:1 ratio with ASD patients. Following the training, ResNet-10t and ResNet-18D have a better estimation performance, with precision, recall, accuracy, F1-score, and the area under the curve being (0.92, 0.93), (0.91, 0.91), (0.90, 0.90), (0.91, 0.91) and (0.97, 0.96), respectively. Compared to ResNet-18D, ResNet-10t was more focused on the distribution of the heat map of the interest region for most chest radiographs from ASD patients. CONCLUSION: The ResNets model is feasible for identifying ASD through children's chest radiographs. ResNet-10t stands out as the preferable estimation model, providing exceptional performance and clear interpretability.


Subject(s)
Echocardiography , Heart Septal Defects, Atrial , Child , Child, Preschool , Female , Humans , Infant , Male , Heart Septal Defects, Atrial/diagnostic imaging , Machine Learning , Radiography , Retrospective Studies
19.
J Vet Cardiol ; 51: 138-144, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38128419

ABSTRACT

A 45-days-old mixed-breed female cat was referred to a veterinary specialty hospital for evaluation due to poor general condition, dyspnea of possible cardiac origin, and a heart murmur. The results of the physical examination, thoracic radiography, and echocardiography led to a diagnosis of hypotrophy of the right ventricle, tricuspid atresia, and atrial septal defect. Cardiovascular pathological findings confirmed the clinical diagnosis in addition to the observation of a ventricular septal defect. To the authors' knowledge, this is the first report of tricuspid atresia with atrial septal defect and ventricular septal defect in a cat.


Subject(s)
Cat Diseases , Heart Septal Defects, Atrial , Heart Septal Defects, Ventricular , Tricuspid Atresia , Female , Cats , Animals , Tricuspid Atresia/diagnostic imaging , Tricuspid Atresia/veterinary , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/abnormalities , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/veterinary , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/veterinary , Echocardiography/veterinary , Cat Diseases/diagnostic imaging
20.
Int J Cardiol ; 395: 131404, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-37777073

ABSTRACT

BACKGROUND: Worsening mitral regurgitation (MR) is a complication of intervention for atrial septal defect (ASD). Little is known about mitral valve (MV) characteristics associated with worsening MR. We aimed to elucidate MR outcomes and predictors of worsening MR after transcatheter ASD closure. METHODS: We analyzed changes in MR from prior to transcatheter ASD closure to 6 months after the procedure and predictors of worsening MR via baseline transthoracic echocardiography in 238 patients (64.7% females; mean age, 53 ± 22 years). RESULTS: Worsening MR was defined as worsening to moderate in patients with less than or equal to mild MR at baseline or vena contracta width increasing of ≥2 mm by 6-month follow-up in patients with moderate MR. Worsening MR was observed in 29 patients (12.2%). The associated echocardiographic findings were pseudoprolapse, hamstringing, stiffness, and anteroposterior and intercommissural mitral annulus diameter in the univariable logistic regression analysis (all P < 0.05). Multivariable analysis after adjusting for age; long-standing persistent atrial fibrillation; and ASD size showed that models combining MV leaflet findings such as pseudoprolapse or hamstringing, or anterior leaflet stiffness with the ratio of the sum of anterior and posterior leaflet lengths to intercommissural mitral annulus diameter were statistically significant for predicting worsening MR (R2 = 0.393, P < 0.001 and R2 = 0.385, P < 0.001, respectively). CONCLUSIONS: Worsening MR after transcatheter ASD closure might depend on MV leaflet findings and annulus size in patients with long-standing persistent atrial fibrillation.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Mitral Valve Insufficiency , Female , Humans , Adult , Middle Aged , Aged , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/complications , Retrospective Studies , Mitral Valve , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...